    Brand Name : R
    Model Number : G08
    Payment Terms : T/T
    • Product Details
    • Company Profile

    G08 General Purpose Gas Flow Analyzer Medical Equipment Test Tool

    Introduction
    The Flow Analyzer Go8, referred to hereafter as the Analyzer, is a general-purpose gas flow analyzer. The Analyzer measures
    unidirectional gas flow, airway pressure and high pressure. The Analyzer can also measure tidal volume, inspiratory peak pressure, positive
    end-expiratory pressure, etc.
    This manual provides a description of the Analyzer and its applications. lt should be used as a guide when using the instrument to analyze ventilators and test lungs.
    Key Features
    Unidirectional flow rate, airway pressure, low pressure, high pressure and oxygen concentration measurement
    Flow, pressure real-time waveform display
    Touch buttons control
    RS232 serial port and can be used for flow calibration

    Intuitive interface, easy to operate
    Easy to carry

    Unpacking and inspection
    Use the following checklist when unpacking the Analyzer. There are no special unpacking instructions, but be careful not to damage the instrument when unpacking it.
    Check the shipping carton is in good condition. lf the shipping carton is damaged, carefully continue unpacking the instrument and note any dents and scratches on the Analyzer. Save the damaged shipping carton and packing material for the carrier inspection.
    lf there is no shipping damage, continue removing the Analyzer from the shipping case. Save the box and packing materials.
    Perform a visual inspection to ensure that the Analyzer is intact and if there is any physical damage, such as bent or broken parts, dents, or scratches. If the Analyzer has been damaged, call the theSiriusmed Service Center immediately.
    After unpacking the Analyzer, check to see if all of the standard accessories listed under the packing list have been included with the analyzer. if anything is missing, contact the Siriusmed ServiceCenter.


    Operating Environmental Conditions
    Temperature Range10 - 40 °c
    Ambient Humidity0- 80 %non-condensing
    Barometric Pressure520-800 mmHg
    Storage Environmental Conditions
    Temperature Range-25 to 50°℃
    Humidity0 -95 % non-condensing
    Power Requirements
    lnput Voltage Range12V DC
    Power Consumption36 VA
    Flow Port
    Flow Range0 -200 LPM
    Accuracy3% of reading or 0.1 LPM
    Resolution0.01 LPM flow <5 LPM;0.1 LPM flow >5 LPM

    Notes

    Flow accuracy is specified for dry air or oxygen.

    Do not use with humidified gases.

    Flow accuracy is obtained by allowing the Analyzer to fully warm up.


    Airway Pressure
    Pressure Range0 - 100 cmH2O
    Accuracy3 % of reading or 0.5 cmH2O
    Resolution0.1 cmH2O
    High Pressure
    Operating Pressure Range0 - 690 kPa
    Accuracy2 % of reading or 5 kPa
    Resolution0.1 kPa
    Barometric Pressure
    Operating Pressure Range120 - 860 mmHg
    Accuracy2 % of reading or 5 mmHg
    Resolution1 mmHg
    Gas Temperature
    Temperature Range0 - 70 °C
    Accuracy2 %FS
    Resolution0.1 °C
    Oxygen Concentration(Optional)
    Range0 - 100 %
    Accuracy2 %FS
    Resolution0.1 °C